Built for the trade.Stocked in Southeastern US warehouses and shipped to dealers nationwide.
Lucera Collection · 82 Series

82 Series fixed window

CPD SUU-M-4

U-factor
0.27–0.50
Solar Heat Gain Coefficient
0.39–0.64
Visible Transmittance
0.56–0.67
Condensation Resistance
39–61

Special order through your SourcePoint dealer, who quotes the glass package, size, color, grids, and hardware for each window. Ratings are the NFRC-certified range across this window's 16 glass packages, double pane.

Specified, quoted, and delivered by your SourcePoint dealer.

82 Series / Fixed82 Series fixed window
82 Series fixed window
SPLUC82002
NFRC certified

Certified ratings by glass package.

Every line is an NFRC product number from the Certification Authorization Report for CPD SUU-M-4, certified at the standard test size for this operator type (FIXD) and valid to 03/07/2031.

Glass packagePanesLow-ESpacerGas fillGridsU-factorSHGCVTCondensation ResistanceNFRC product number
S116 / Air / Clear (3mm/3mm) 22mm IG20.057(2)A1-DAIR (100)None0.330.480.655100001-00001
20.057(2)A1-DAIR (100)Simulated divided lite0.330.430.585100001-00002
20.057(2)A1-DAIR (100)Grids between glass0.350.430.585100002-00001
20.057(2)A1-DAIR (100)Simulated divided lite0.350.430.585100002-00002
20.057(2)TS-DAIR (100)None0.320.480.655600033-00001
20.057(2)TS-DAIR (100)Simulated divided lite0.320.430.585600033-00002
20.057(2)TS-DAIR (100)Grids between glass0.340.430.585600034-00001
20.057(2)TS-DAIR (100)Simulated divided lite0.340.430.585600034-00002
S116 / ARG90 / Clear (3mm/3mm) 22mm IG20.057(2)A1-DARG (90)None0.300.480.655300003-00001
20.057(2)A1-DARG (90)Simulated divided lite0.300.430.585300003-00002
20.057(2)A1-DARG (90)Grids between glass0.310.430.585300004-00001
20.057(2)A1-DARG (90)Simulated divided lite0.310.430.585300004-00002
20.057(2)TS-DARG (90)None0.280.480.656000035-00001
20.057(2)TS-DARG (90)Simulated divided lite0.280.430.586000035-00002
20.057(2)TS-DARG (90)Grids between glass0.300.430.586000036-00001
20.057(2)TS-DARG (90)Simulated divided lite0.300.430.586000036-00002
S116 / Air / Clear (5mm/5mm) 22mm IG20.076(2)A1-DAIR (100)None0.330.460.644800005-00001
20.076(2)A1-DAIR (100)Simulated divided lite0.330.410.574800005-00002
20.076(2)A1-DAIR (100)Grids between glass0.390.410.574800006-00001
20.076(2)A1-DAIR (100)Simulated divided lite0.390.410.574800006-00002
20.076(2)TS-DAIR (100)None0.320.460.645400037-00001
20.076(2)TS-DAIR (100)Simulated divided lite0.320.410.575400037-00002
20.076(2)TS-DAIR (100)Grids between glass0.370.410.575300038-00001
20.076(2)TS-DAIR (100)Simulated divided lite0.370.410.575300038-00002
S116 / ARG90 / Clear (5mm/5mm) 22mm IG20.076(2)A1-DARG (90)None0.300.460.645100007-00001
20.076(2)A1-DARG (90)Simulated divided lite0.300.410.575100007-00002
20.076(2)A1-DARG (90)Grids between glass0.350.410.575100008-00001
20.076(2)A1-DARG (90)Simulated divided lite0.350.410.575100008-00002
20.076(2)TS-DARG (90)None0.280.460.645700039-00001
20.076(2)TS-DARG (90)Simulated divided lite0.280.410.575700039-00002
20.076(2)TS-DARG (90)Grids between glass0.330.410.575700040-00001
20.076(2)TS-DARG (90)Simulated divided lite0.330.410.575700040-00002
Clear / Air / Clear (3mm/3mm) 22mm IG2—A1-DAIR (100)None0.460.640.674100009-00001
2—A1-DAIR (100)Simulated divided lite0.460.570.604100009-00002
2—A1-DAIR (100)Grids between glass0.470.570.604100010-00001
2—A1-DAIR (100)Simulated divided lite0.470.570.604100010-00002
2—TS-DAIR (100)None0.450.640.674500041-00001
2—TS-DAIR (100)Simulated divided lite0.450.570.604500041-00002
2—TS-DAIR (100)Grids between glass0.460.570.604500042-00001
2—TS-DAIR (100)Simulated divided lite0.460.570.604500042-00002
Clear / Air / Clear (5mm/5mm) 22mm IG2—A1-DAIR (100)None0.460.600.654000011-00001
2—A1-DAIR (100)Simulated divided lite0.460.540.584000011-00002
2—A1-DAIR (100)Grids between glass0.500.540.584000012-00001
2—A1-DAIR (100)Simulated divided lite0.500.540.584000012-00002
2—TS-DAIR (100)None0.450.600.654400043-00001
2—TS-DAIR (100)Simulated divided lite0.450.540.584400043-00002
2—TS-DAIR (100)Grids between glass0.490.540.584200044-00001
2—TS-DAIR (100)Simulated divided lite0.490.540.584200044-00002
S116 / ARG90 / S116 (3mm/3mm) 22mm IG20.057(2), 0.057(3)A1-DARG (90)None0.290.440.645400013-00001
20.057(2), 0.057(3)A1-DARG (90)Simulated divided lite0.290.400.575400013-00002
20.057(2), 0.057(3)A1-DARG (90)Grids between glass0.300.400.575400014-00001
20.057(2), 0.057(3)A1-DARG (90)Simulated divided lite0.300.400.575400014-00002
20.057(2), 0.057(3)TS-DARG (90)None0.270.440.646100045-00001
20.057(2), 0.057(3)TS-DARG (90)Simulated divided lite0.270.400.576100045-00002
20.057(2), 0.057(3)TS-DARG (90)Grids between glass0.290.400.576100046-00001
20.057(2), 0.057(3)TS-DARG (90)Simulated divided lite0.290.400.576100046-00002
S116 / ARG90 / S116 (5mm/5mm) 22mm IG20.076(2), 0.076(3)A1-DARG (90)None0.290.430.635200015-00001
20.076(2), 0.076(3)A1-DARG (90)Simulated divided lite0.290.390.565200015-00002
20.076(2), 0.076(3)A1-DARG (90)Grids between glass0.340.390.565200016-00001
20.076(2), 0.076(3)A1-DARG (90)Simulated divided lite0.340.390.565200016-00002
20.076(2), 0.076(3)TS-DARG (90)None0.270.430.635800047-00001
20.076(2), 0.076(3)TS-DARG (90)Simulated divided lite0.270.390.565800047-00002
20.076(2), 0.076(3)TS-DARG (90)Grids between glass0.320.390.565800048-00001
20.076(2), 0.076(3)TS-DARG (90)Simulated divided lite0.320.390.565800048-00002
S116 / Air / Clear (3mm/3mm) 18mm IG20.057(2)A1-DAIR (100)None0.320.480.655000017-00001
20.057(2)A1-DAIR (100)Simulated divided lite0.320.430.585000017-00002
20.057(2)A1-DAIR (100)Grids between glass0.380.430.585000018-00001
20.057(2)A1-DAIR (100)Simulated divided lite0.380.430.585000018-00002
20.057(2)TS-DAIR (100)None0.310.480.655400049-00001
20.057(2)TS-DAIR (100)Simulated divided lite0.310.430.585400049-00002
20.057(2)TS-DAIR (100)Grids between glass0.370.430.585200050-00001
20.057(2)TS-DAIR (100)Simulated divided lite0.370.430.585200050-00002
S116 / ARG90 / Clear (3mm/3mm) 18mm IG20.057(2)A1-DARG (90)None0.290.480.655200019-00001
20.057(2)A1-DARG (90)Simulated divided lite0.290.430.585200019-00002
20.057(2)A1-DARG (90)Grids between glass0.340.430.585200020-00001
20.057(2)A1-DARG (90)Simulated divided lite0.340.430.585200020-00002
20.057(2)TS-DARG (90)None0.280.480.655800051-00001
20.057(2)TS-DARG (90)Simulated divided lite0.280.430.585800051-00002
20.057(2)TS-DARG (90)Grids between glass0.330.430.585700052-00001
20.057(2)TS-DARG (90)Simulated divided lite0.330.430.585700052-00002
S116 / Air / Clear (5mm/5mm) 19mm IG20.076(2)A1-DAIR (100)None0.360.460.644600021-00001
20.076(2)A1-DAIR (100)Simulated divided lite0.360.420.574600021-00002
20.076(2)A1-DAIR (100)Grids between glass0.390.420.574600022-00001
20.076(2)A1-DAIR (100)Simulated divided lite0.390.420.574600022-00002
20.076(2)TS-DAIR (100)None0.350.460.645000053-00001
20.076(2)TS-DAIR (100)Simulated divided lite0.350.420.575000053-00002
20.076(2)TS-DAIR (100)Grids between glass0.380.420.575000054-00001
20.076(2)TS-DAIR (100)Simulated divided lite0.380.420.575000054-00002
S116 / ARG90 / Clear (5mm/5mm) 19mm IG20.076(2)A1-DARG (90)None0.310.460.644900023-00001
20.076(2)A1-DARG (90)Simulated divided lite0.310.410.574900023-00002
20.076(2)A1-DARG (90)Grids between glass0.350.410.574900024-00001
20.076(2)A1-DARG (90)Simulated divided lite0.350.410.574900024-00002
20.076(2)TS-DARG (90)None0.300.460.645400055-00001
20.076(2)TS-DARG (90)Simulated divided lite0.300.410.575400055-00002
20.076(2)TS-DARG (90)Grids between glass0.340.410.575400056-00001
20.076(2)TS-DARG (90)Simulated divided lite0.340.410.575400056-00002
Clear / Air / Clear (3mm/3mm) 18mm IG2—A1-DAIR (100)None0.460.640.674100025-00001
2—A1-DAIR (100)Simulated divided lite0.460.570.604100025-00002
2—A1-DAIR (100)Grids between glass0.500.570.604100026-00001
2—A1-DAIR (100)Simulated divided lite0.500.570.604100026-00002
2—TS-DAIR (100)None0.450.640.674300057-00001
2—TS-DAIR (100)Simulated divided lite0.450.570.604300057-00002
2—TS-DAIR (100)Grids between glass0.490.570.604200058-00001
2—TS-DAIR (100)Simulated divided lite0.490.570.604200058-00002
Clear / Air / Clear (5mm/5mm) 19mm IG2—A1-DAIR (100)None0.480.600.653900027-00001
2—A1-DAIR (100)Simulated divided lite0.480.540.583900027-00002
2—A1-DAIR (100)Grids between glass0.500.540.583900028-00001
2—A1-DAIR (100)Simulated divided lite0.500.540.583900028-00002
2—TS-DAIR (100)None0.470.600.654200059-00001
2—TS-DAIR (100)Simulated divided lite0.470.540.584200059-00002
2—TS-DAIR (100)Grids between glass0.490.540.584200060-00001
2—TS-DAIR (100)Simulated divided lite0.490.540.584200060-00002
S116 / ARG90 / S116 (3mm/3mm) 18mm IG20.057(2), 0.057(3)A1-DARG (90)None0.280.440.645300029-00001
20.057(2), 0.057(3)A1-DARG (90)Simulated divided lite0.280.400.575300029-00002
20.057(2), 0.057(3)A1-DARG (90)Grids between glass0.330.400.575300030-00001
20.057(2), 0.057(3)A1-DARG (90)Simulated divided lite0.330.400.575300030-00002
20.057(2), 0.057(3)TS-DARG (90)None0.270.440.645900061-00001
20.057(2), 0.057(3)TS-DARG (90)Simulated divided lite0.270.400.575900061-00002
20.057(2), 0.057(3)TS-DARG (90)Grids between glass0.320.400.575800062-00001
20.057(2), 0.057(3)TS-DARG (90)Simulated divided lite0.320.400.575800062-00002
S116 / ARG90 / S116 (5mm/5mm) 19mm IG20.076(2), 0.076(3)A1-DARG (90)None0.300.430.635000031-00001
20.076(2), 0.076(3)A1-DARG (90)Simulated divided lite0.300.390.565000031-00002
20.076(2), 0.076(3)A1-DARG (90)Grids between glass0.330.390.565000032-00001
20.076(2), 0.076(3)A1-DARG (90)Simulated divided lite0.330.390.565000032-00002
20.076(2), 0.076(3)TS-DARG (90)None0.290.430.635500063-00001
20.076(2), 0.076(3)TS-DARG (90)Simulated divided lite0.290.390.565500063-00002
20.076(2), 0.076(3)TS-DARG (90)Grids between glass0.320.390.565500064-00001
20.076(2), 0.076(3)TS-DARG (90)Simulated divided lite0.320.390.565500064-00002

Glass packages are listed as printed on the NFRC Certification Authorization Report.

Ratings are certified at the NFRC standard size for each operator type. Air Leakage appears where a report certifies it. Grids between glass and simulated divided lites are rated separately from the no-grid line.

Options

Options and prep.

Options are chosen per window and carried on the item code. Glass package and grids set the NFRC ratings; the rated figures for every combination are in the technical documentation below.

Casements are handed and swing out or in by model; the item code carries the hand. Hung and slider windows are not handed: on a single hung the top sash operates, on a single slider one sash operates. Every window is sized to order; frame and rough-opening dimensions are confirmed on the quote.

Colors and textures
Multiple colors and texturesQuoted per window by your SourcePoint dealer.
Grids
None, grids between glass, or simulated divided lite, 3/4" bar. Grids change solar heat gain and visible transmittance; each grid option is rated.Patterns quoted per window.
Glass packages
Double pane (18 to 26 mm units) on both series; triple pane (39 or 42 mm units) on the 70 Series; clear or Low-E; air or argon fill; two spacer types. 14 packages on the 70 Series, 16 on the 82 Series, each with its own NFRC product numbers.Every package is special order, quoted per window. Packages are named as printed on the NFRC report.
Hardware and screens
Specified per window and quoted by your SourcePoint dealer.
Configurations
Fixed · Casement · Double hung · Single hung · Slider70 Series: fixed, outswing and inswing casement. 82 Series: fixed, double hung, single hung, single and double slider.
Nominal stock sizes
Sized to order; every window is quoted by series, operation, and size.
Hand and swing
Casement: outswing (70 Series) or inswing (70 Series), left or right hand. Fixed, hung, slider: none.
Glass
By NFRC glass package; see technical documentation.
Finish
Multiple colors and textures, quoted per window
Jamb depth
70 mm profile on the 70 Series, 82 mm on the 82 Series; frame type quoted per order.
Prep
No bore or backset. Locking hardware and handles are fitted at the factory and ship in the window.Hardware by operation, handle finish, and screens are quoted per window.
Documents

Documents

Current documents for this Collection. Warranty claims go through your selling dealer.

Also in the Collection

Other Lucera Collection windows.

7 more windows, each with its NFRC ratings by glass package. See every Lucera Collection window

70 Series fixed window70 Series · Fixed

70 Series fixed window

CPD SUU-M-1
U-factor
0.18–0.45
Solar Heat Gain Coefficient
0.23–0.60
Visible Transmittance
0.39–0.64
Condensation Resistance
44–71
14 glass packages · Double and triple pane
70 Series outswing casement window70 Series · Outswing casement

70 Series outswing casement window

CPD SUU-M-2
U-factor
0.22–0.42
Solar Heat Gain Coefficient
0.17–0.42
Visible Transmittance
0.27–0.44
Condensation Resistance
42–72
14 glass packages · Double and triple pane
70 Series inswing casement window70 Series · Inswing casement

70 Series inswing casement window

CPD SUU-M-3
U-factor
0.22–0.40
Solar Heat Gain Coefficient
0.15–0.39
Visible Transmittance
0.25–0.41
Condensation Resistance
43–73
14 glass packages · Double and triple pane
82 Series double hung window82 Series · Double hung

82 Series double hung window

CPD SUU-M-5
U-factor
0.28–0.50
Solar Heat Gain Coefficient
0.36–0.60
Visible Transmittance
0.52–0.63
Condensation Resistance
39–59
16 glass packages · Double pane
82 Series single hung window82 Series · Single hung

82 Series single hung window

CPD SUU-M-6
U-factor
0.27–0.50
Solar Heat Gain Coefficient
0.37–0.61
Visible Transmittance
0.54–0.64
Condensation Resistance
38–59
16 glass packages · Double pane
82 Series single slider window82 Series · Single slider

82 Series single slider window

CPD SUU-M-7
U-factor
0.27–0.50
Solar Heat Gain Coefficient
0.37–0.62
Visible Transmittance
0.54–0.65
Condensation Resistance
39–59
16 glass packages · Double pane
82 Series double slider window82 Series · Double slider

82 Series double slider window

CPD SUU-M-8
U-factor
0.28–0.51
Solar Heat Gain Coefficient
0.37–0.61
Visible Transmittance
0.53–0.64
Condensation Resistance
38–60
16 glass packages · Double pane
For builders and architects

Specify the Lucera Collection. Your dealer handles the rest.

Your SourcePoint dealer quotes the Lucera Collection alongside the rest of the range: six materials, one brand, one warranty, one call. Confirms size, operation, and glass package, and delivers the complete unit to the job.

(888) 821-DOOR